Physics > Instrumentation and Detectors
[Submitted on 16 Jul 2023]
Title:Seven-probe scintillator dosimeter for treatment verification in HDR-brachytherapy
View PDFAbstract:Purpose: We introduce a novel concept of a compact multiprobe scintillator detector and demonstrate its applicability in HDR-brachytherapy. Our fabricated seven-probe system is sufficiently narrow to be inserted in a brachytherapy needle or in a catheter.
Methods: Our multiprobe detection system results from the parallel implementation of a miniaturized scintillator detector at the end of a bundle of seven fibers. The resulting system, which is narrower than 320 microns, is tested with a MicroSelectron 9.1 Ci Ir-192 HDR afterloader, in a water phantom. The detection signals from all seven probes are simultaneously read with an sCMOS camera (at a rate of 0.06 s). The camera is coupled to a chromatic filter to cancel Cerenkov signal induced within the fibers upon exposure. By implementing an aperiodic array of six scintillating cells along the bundle axis (one probe is kept bare to assess the stem effect), we first determine the range of inter-probe spacings leading to optimal source tracking accuracy. Then, three different source tracking algorithms involving sequentially or simultaneously all the scintillating probes are tested and compared. In each case, dwell positions are assessed from dose measurements and compared to the treatment plan. Dwell time is also determined and compared to the treatment plan.
Results: The optimum inter-probe spacing for an accurate source tracking ranges from 15 mm to 35 mm. The optimum detection algorithm consists of adding the readout signals from all detector probes. In that case, the error to the planned dwell positions is of 0.01+/-0.14 mm and 0.02+/-0.29 mm at spacings between the source and detector axes of 5.5 and 40 mm, respectively. Using this approach, the average deviations to the expected dwell time are of -0.006+/-0.009 s and -0.008+/-0.058 s, at spacings between source and probe axes of 5.5 mm and 20 mm, respectively.
Submission history
From: Thierry Grosjean [view email][v1] Sun, 16 Jul 2023 19:54:51 UTC (6,938 KB)
Current browse context:
physics
Change to browse by:
References & Citations
Bibliographic and Citation Tools
Bibliographic Explorer (What is the Explorer?)
Connected Papers (What is Connected Papers?)
Litmaps (What is Litmaps?)
scite Smart Citations (What are Smart Citations?)
Code, Data and Media Associated with this Article
alphaXiv (What is alphaXiv?)
CatalyzeX Code Finder for Papers (What is CatalyzeX?)
DagsHub (What is DagsHub?)
Gotit.pub (What is GotitPub?)
Hugging Face (What is Huggingface?)
Papers with Code (What is Papers with Code?)
ScienceCast (What is ScienceCast?)
Demos
Recommenders and Search Tools
Influence Flower (What are Influence Flowers?)
CORE Recommender (What is CORE?)
arXivLabs: experimental projects with community collaborators
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.